<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Madgetech &#187; Products</title>
	<atom:link href="http://www.madgetech.co.nz/shop/feed/?product_tag=strain" rel="self" type="application/rss+xml" />
	<link>http://www.madgetech.co.nz</link>
	<description>Advanced Technical Services are the New Zealand distributors for Madgetech Data logging equipment.</description>
	<lastBuildDate>Mon, 12 Jun 2017 07:21:17 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=4.1.22</generator>
	<item>
		<title>Bridge101A Data Logger</title>
		<link>http://www.madgetech.co.nz/shop/bridge-strain/bridge101a-data-logger/</link>
		<comments>http://www.madgetech.co.nz/shop/bridge-strain/bridge101a-data-logger/#comments</comments>
		<pubDate>Fri, 06 Mar 2015 03:08:11 +0000</pubDate>
		<dc:creator><![CDATA[sjp156]]></dc:creator>
		
		<guid isPermaLink="false">http://test.madgetech.co.nz/shop/uncategorized/bridge101a-data-logger/</guid>
		<description><![CDATA[Bridge/Strain Gauge Data Logger. The Bridge101A supplies a 2.5V excitation voltage and accepts voltage signals from strain gauges, load cells and other low-level, DC voltage sources.]]></description>
				<content:encoded><![CDATA[<p style="text-align: justify;">The Bridge101A Data Logger measures and records voltage, typically used in conjunction with strain gauges, load cells or other low-level DC voltage sources. This device is designed to accurately measure and record the output of the gauge to determine parameter levels such as stress, torque, strain, and pressure on a structure or item over a period of time.</p>
<p style="text-align: justify;">
<p style="text-align: justify;">Available in three different measurement ranges (±30 mV, ±160 mV or ±1200 mV), the Bridge101A offers a reading rate of up to 4 Hz with memory capacity of 1,000,000 readings (memory wrap optional). The device can be configured to start at a specified date and time up to 24 months in advance and the pushbutton start/stop feature allows the user to initiate or cease logging data in the field if desired.</p>
<p style="text-align: justify;">
<p style="text-align: justify;">The MadgeTech Data Logger Software offers user programmable Engineering Units which allows collected data to be presented in the established unit being measured. Equipped with endless data analysis and reporting tools, the MadgeTech software simplifies device management and provides the user with graph, tabular or summary reports with the ability to export data to Excel as needed.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.madgetech.co.nz/shop/bridge-strain/bridge101a-data-logger/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Bridge120 Data Logger</title>
		<link>http://www.madgetech.co.nz/shop/bridge-strain/bridge120-data-logger/</link>
		<comments>http://www.madgetech.co.nz/shop/bridge-strain/bridge120-data-logger/#comments</comments>
		<pubDate>Fri, 06 Mar 2015 03:08:12 +0000</pubDate>
		<dc:creator><![CDATA[sjp156]]></dc:creator>
		
		<guid isPermaLink="false">http://test.madgetech.co.nz/shop/uncategorized/bridge120-data-logger/</guid>
		<description><![CDATA[Differential Input, 20 Hz Bridge/Strain Data Logger. The Bridge120 supplies a 2.5 V excitation voltage and accepts voltage signals from strain gauges, load cells and other low-level, DC voltage sources.]]></description>
				<content:encoded><![CDATA[<p style="text-align: justify;">The Bridge120 is a battery powered, miniature, stand alone bridge/strain data logger. The device features a 20 Hz processing speed and a real-time clock module. The Bridge120 supplies a 2.5 V excitation voltage and accepts voltage signals from strain gauges, load cells and other low-level, DC voltage sources. The data logger is perfect for monitoring stress, torque, strain, pressure conditions and data from many other sensors/transducers. User programmable Engineering Units allow the data to be presented in Volts, milliVolts, microVolts as well as the proper units being measured.</p>
<p style="text-align: justify;">This easy-to-use device can measure and record data for up to 32,767 measurements per channel. The storage medium is non-volatile solid state memory, providing maximum data security even if the battery becomes discharged. The device can be started and stopped directly from your computer and its small size allows it to fit almost anywhere. The Bridge120 data logger makes data retrieval quick and easy. Simply plug it into an empty COM or USB port and our user-friendly software does the rest.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.madgetech.co.nz/shop/bridge-strain/bridge120-data-logger/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
